STEEL-01-01 Chapter 01 · Structural Fasteners and Connections

Bolted Connections (Bearing & Friction Grip HSFG Bolts — IS 800:2007)

In this chapter (4 topics)
On this page
  1. 1. Topic Title and Metadata
  2. 2. Prerequisites and Engineering Context
  3. 3. Fundamental Physical and Engineering Principles
  4. 3.1 Physical and Mechanical Properties of Structural Steel (IS 800:2007 Cl. 2.2.4)
  5. 3.2 Partial Safety Factors for Materials (γm) per IS 800:2007 Table 5
  6. 3.3 Classification and Mechanics of Bolted Fasteners
  7. 4. Rigorous Mathematical Derivations & Code Formulations
  8. 4.1 Standard Clearance Hole Diameters (d0) (IS 800:2007 Table 19)
  9. 4.2 Bolt Areas: Shank Area (Asb) vs Net Tensile Stress Area (Anb)
  10. 4.3 Design Capacity of Bearing-Type Bolts (IS 800:2007 Cl. 10.3)
  11. 4.4 Design Capacity of HSFG Friction-Grip Bolts (IS 800:2007 Cl. 10.4)
  12. 4.5 Plate Tensile Rupture & Joint Efficiency
  13. 5. Detailing Rules and Codal Mandates (IS 800:2007 Cl. 10.2)
  14. 6. SVG Diagrams and Visual Explanations
  15. 6.1 Bolted Connection Detailing Geometry & The Six Failure Modes
  16. 6.2 Bearing Bolts vs HSFG Friction Grip Fasteners & Interaction Curves
  17. 7. Solved Numerical Examples
  18. 7.1 Example 1: Design of a Bearing-Type Bolted Lap Joint under Tension
  19. 7.2 Example 2: HSFG (Slip-Critical) Double Cover Butt Joint
  20. 7.3 Example 3: Verification of Bolted Connection under Combined Shear and Tension
  21. 8. Common Pitfalls, Misconceptions, and Examination Traps
  22. 9. Comparative Analysis and Summary Tables
  23. 9.1 Bearing-Type Bolts vs High-Strength Friction Grip (HSFG) Bolts
  24. 10. Exam-Specific Focus and Formula Cheat Sheet
  25. 10.1 Must-Remember Formulas for Quick Objective Calculations
  26. 11. Practice Problems and Self-Assessment with Numerical Answers
  27. 12. Standard References and Further Reading

1. Topic Title and Metadata

Attribute Specification
Topic ID STEEL-01-01
Module / Subject Subject 06: Design of Steel Structures (IS 800:2007)
Chapter Chapter 01: Structural Steel Fundamentals & Connection Design
Topic Title Bolted Connections (Bearing & Friction Grip HSFG Bolts, Shear, Bearing & Tensile Capacities)
Applicable Standards IS 800:2007 (General Construction in Steel — Code of Practice), IS 1367, IS 3757, IS 4000, AISC 360-16, Eurocode 3 (EN 1993-1-8)
Target Examinations GATE CE, UPSC ESE (Paper-I), SSC JE, State PSC AE/JE, RRB JE
Primary Authorship Civil Engineering Autonomous Master Repository
Verification Gate Level 1 through Level 7 (Mathematical Recalculation, Codal Compliance, SVG Validation)

2. Prerequisites and Engineering Context

To master the limit state design of structural steel bolted fasteners, the student and structural engineer must be proficient in:

  • Mechanics of Materials (SOM-01-01, SOM-05-01): Direct shear stress across cross-sections, contact/bearing stresses on curved cylindrical boundaries, and net tensile stress concentration.
  • Ductile vs Brittle Plasticity (SOM-01-02): Yield plateau, strain hardening, ultimate tensile strength (fuf_u), and elongation percentage.
  • Limit State Design Philosophy (RCC-01-01): Partial safety factors for materials (γm\gamma_m) and loads (γf\gamma_f), characteristic loads, and limit states of strength vs serviceability.

Structural steel connections are the critical links that transfer internal axial forces, shear forces, and bending moments between individual members (beams, columns, trusses, and bracing). Statistically, structural collapses in steel buildings and bridges initiate at faulty or under-designed connections rather than within member bodies. Modern structural practice predominantly utilizes bolted connections (for fast, weather-independent site erection) and welded connections (for rigid factory prefabrication).


3. Fundamental Physical and Engineering Principles

3.1 Physical and Mechanical Properties of Structural Steel (IS 800:2007 Cl. 2.2.4)

For all standard structural steels conforming to IS 2062:

  • Mass Density (ρ\rho): 7850 kg/m37850\text{ kg/m}^3 (78.5 kN/m378.5\text{ kN/m}^3).
  • Modulus of Elasticity (EE): 2.0×105 N/mm22.0 \times 10^5\text{ N/mm}^2 (200 GPa200\text{ GPa}).
  • Poisson's Ratio (μ\mu or ν\nu):
    • In elastic range: μ=0.30\mu = 0.30
    • In plastic range: μ=0.50\mu = 0.50 (incompressible yielding)
  • Shear Modulus (GG): G=E2(1+μ)=2.0×1052(1+0.30)≈76.92×103 N/mm2≈0.77×105 N/mm2G = \frac{E}{2(1 + \mu)} = \frac{2.0 \times 10^5}{2(1 + 0.30)} \approx 76.92 \times 10^3\text{ N/mm}^2 \approx 0.77 \times 10^5\text{ N/mm}^2
  • Coefficient of Linear Thermal Expansion (α\alpha): 12×10−6/°C12 \times 10^{-6} /\text{°C}.

3.2 Partial Safety Factors for Materials (γm\gamma_m) per IS 800:2007 Table 5

In limit state design, nominal material resistances are divided by partial safety factors:

Structural Condition Governing Mechanism Partial Safety Factor (γm\gamma_m)
Member Resistance Yielding of gross cross-section γm0=1.10\gamma_{m0} = \mathbf{1.10}
Member Resistance Ultimate tensile rupture of net section γm1=1.25\gamma_{m1} = \mathbf{1.25}
Member Resistance Buckling of compression members γm0=1.10\gamma_{m0} = \mathbf{1.10}
Bolts (Bearing Type) Shear, bearing, and tension resistance γmb=1.25\gamma_{mb} = \mathbf{1.25}
Bolts (HSFG Friction) Slip resistance at serviceability limit state γmf=1.10\gamma_{mf} = \mathbf{1.10}
Bolts (HSFG Friction) Slip resistance at ultimate limit state γmf=1.25\gamma_{mf} = \mathbf{1.25}
Welds Shop fabrication γmw=1.25\gamma_{mw} = \mathbf{1.25}
Welds Field / Site fabrication γmw=1.50\gamma_{mw} = \mathbf{1.50}

3.3 Classification and Mechanics of Bolted Fasteners

Bolts used in structural engineering are categorized into three broad classes:

1. Black Bolts (Ordinary / Unfinished Bolts)

  • Manufactured from mild steel hexagonal rods conforming to IS 1363 (Property Class 4.6, 5.6).
  • Property Class Notation (e.g., Class 4.6):
    • First digit ×100\times 100 = Nominal ultimate tensile strength: fub=4×100=400 N/mm2f_{ub} = 4 \times 100 = \mathbf{400\text{ N/mm}^2}.
    • Second digit ×0.1×fub\times 0.1 \times f_{ub} = Nominal yield strength: fyb=0.6×400=240 N/mm2f_{yb} = 0.6 \times 400 = \mathbf{240\text{ N/mm}^2}.
  • Installed in standard clearance holes (d0=d+1 to 3 mmd_0 = d + 1\text{ to } 3\text{ mm}).
  • Load Transfer: As load is applied, the connected plates first slip past each other until the bolt hole edge physically bears against the cylindrical bolt shank. Load is transferred through bearing pressure on the hole wall and transverse shear across the bolt shank.

2. Turned and Fitted Bolts

  • Machine-turned hexagonal bolts fitted into reamed, close-tolerance holes with zero clearance (d0≈dd_0 \approx d). Eliminates initial joint slip but involves high manufacturing costs.

3. High-Strength Friction Grip (HSFG) Bolts

  • Manufactured from quenched and tempered medium carbon or alloy steel conforming to IS 3757 (Property Class 8.8, 10.9).
    • Class 8.8: fub=800 N/mm2,fyb=640 N/mm2f_{ub} = 800\text{ N/mm}^2, f_{yb} = 640\text{ N/mm}^2.
    • Class 10.9: fub=1000 N/mm2,fyb=900 N/mm2f_{ub} = 1000\text{ N/mm}^2, f_{yb} = 900\text{ N/mm}^2.
  • Tightened using calibrated torque wrenches or load-indicating washers to a precise initial tension (proof load F0F_0).
  • Load Transfer: The massive clamping force clamps the connected plates tightly together. Applied shear forces are resisted purely by interfacial friction between the plate surfaces.
  • Advantages:
    1. No joint slip under service loads (rigid joint behavior).
    2. Excellent fatigue and dynamic impact resistance (no stress concentration at hole bearing).
    3. Bolts are subjected to static tension; alternating external shear does not induce shear stress reversals in the shank.

4. Rigorous Mathematical Derivations & Code Formulations

4.1 Standard Clearance Hole Diameters (d0d_0) (IS 800:2007 Table 19)

To permit easy alignment and insertion during erection, holes drilled or punched in steel plates are slightly larger than the nominal bolt diameter dd:

d0=d+Δd\boxed{d_0 = d + \Delta d}
Nominal Bolt Diameter (dd) Standard Clearance (Δd\Delta d) Standard Hole Diameter (d0d_0)
12 mm≤d≤14 mm12\text{ mm} \le d \le 14\text{ mm} +1.0 mm+1.0\text{ mm} d+1.0 mmd + 1.0\text{ mm}
16 mm≤d≤24 mm16\text{ mm} \le d \le 24\text{ mm} +2.0 mm+2.0\text{ mm} d+2.0 mmd + 2.0\text{ mm}
d>24 mmd > 24\text{ mm} +3.0 mm+3.0\text{ mm} d+3.0 mmd + 3.0\text{ mm}

Example: A 20 mm20\text{ mm} nominal diameter bolt requires a standard hole diameter of d0=20+2=22 mmd_0 = 20 + 2 = 22\text{ mm}.

4.2 Bolt Areas: Shank Area (AsbA_{sb}) vs Net Tensile Stress Area (AnbA_{nb})

A standard bolt consists of an unthreaded cylindrical shank and a threaded portion:

  • Nominal Shank Area (AsbA_{sb}): Gross cross-sectional area of unthreaded shank: Asb=π4d2A_{sb} = \frac{\pi}{4} d^2
  • Net Tensile Stress Area at Threads (AnbA_{nb}): Area at the root of the thread. Per IS 800:2007 Cl. 10.3.3: Anb≈0.78⋅Asb=0.78(π4d2)\boxed{A_{nb} \approx 0.78 \cdot A_{sb} = 0.78 \left( \frac{\pi}{4} d^2 \right)}

4.3 Design Capacity of Bearing-Type Bolts (IS 800:2007 Cl. 10.3)

4.3.1 Shear Capacity of Bolt (VdsbV_{dsb})

Under transverse shear, the bolt can fail by shearing across one or more cross-sections. The design shear strength of a bolt is:

Vdsb=Vnsbγmb=fub3⋅γmb⋅(nnAnb+nsAsb)\boxed{V_{dsb} = \frac{V_{nsb}}{\gamma_{mb}} = \frac{f_{ub}}{\sqrt{3} \cdot \gamma_{mb}} \cdot \left( n_n A_{nb} + n_s A_{sb} \right)}

where:

  • fubf_{ub} = Ultimate tensile strength of the bolt material (400 N/mm2400\text{ N/mm}^2 for Class 4.6).
  • fub3\frac{f_{ub}}{\sqrt{3}} = Shear yield strength per von Mises failure criterion.
  • γmb=1.25\gamma_{mb} = 1.25 = Partial safety factor for bolt material (Table 5).
  • nnn_n = Number of shear planes intercepting the threaded portion of the bolt shank.
  • nsn_s = Number of shear planes intercepting the unthreaded cylindrical shank.
  • AnbA_{nb} = Net tensile stress area at threads (≈0.78Asb\approx 0.78 A_{sb}).
  • AsbA_{sb} = Nominal shank area (π4d2\frac{\pi}{4} d^2).
  • Conservative Rule: If the location of the thread run-out is not verified, assume all shear planes pass through the threads (ns=0,nn=total shear planesn_s = 0, n_n = \text{total shear planes}).
    • For single shear lap joint: Vdsb=fub⋅Anb3⋅1.25≈0.369⋅fubAnbV_{dsb} = \frac{f_{ub} \cdot A_{nb}}{\sqrt{3} \cdot 1.25} \approx 0.369 \cdot f_{ub} A_{nb}.
    • For double shear butt joint: Vdsb=2×fub⋅Anb3⋅1.25V_{dsb} = 2 \times \frac{f_{ub} \cdot A_{nb}}{\sqrt{3} \cdot 1.25}.

4.3.2 Bearing Capacity of Bolt on Connected Plate (VdpbV_{dpb})

Bearing failure occurs when the cylindrical surface of the bolt shank crushes against the hole wall in the plate, causing hole elongation or shank indentation. The design bearing strength of a bolt is governed by:

Vdpb=Vnpbγmb=2.5⋅kb⋅d⋅t⋅fuγmb\boxed{V_{dpb} = \frac{V_{npb}}{\gamma_{mb}} = \frac{2.5 \cdot k_b \cdot d \cdot t \cdot f_u}{\gamma_{mb}}}

where:

  • dd = Nominal diameter of bolt.
  • tt = Aggregate thickness of connected plates experiencing bearing in the same direction:
    • For a lap joint: t=min⁡(t1,t2)t = \min(t_1, t_2).
    • For a double cover butt joint: t=min⁡(tmain,2⋅tcover)t = \min(t_{\text{main}}, 2 \cdot t_{\text{cover}}).
  • fuf_u = Smaller of the ultimate tensile strength of the plate (fuf_u) and the bolt (fubf_{ub}).
  • γmb=1.25\gamma_{mb} = 1.25.
  • kbk_b = Bearing factor accounting for end distance, pitch, and relative material strengths:
kb=min⁡{e3d0,  (p3d0−0.25),  fubfu,  1.0}\boxed{k_b = \min \left\{ \frac{e}{3 d_0}, \; \left(\frac{p}{3 d_0} - 0.25\right), \; \frac{f_{ub}}{f_u}, \; 1.0 \right\}}

where:

  • ee = End distance (measured from center of outer bolt hole to plate edge parallel to load).
  • pp = Pitch (center-to-center spacing of adjacent bolts along the direction of load).
  • d0d_0 = Standard clearance hole diameter.

Physical Significance of kbk_b Terms:

  1. e3d0\frac{e}{3 d_0}: Prevents end tear-out/splitting of the plate ahead of the bolt.
  2. p3d0−0.25\frac{p}{3 d_0} - 0.25: Prevents shear splitting between adjacent bolt holes.
  3. fubfu\frac{f_{ub}}{f_u}: Protects against bolt shank crushing when plate steel is stronger than bolt steel.
  4. 1.01.0: Upper limit representing full triaxial bearing plasticization.

4.3.3 Tensile Capacity of Bolt (TdbT_{db}) (IS 800:2007 Cl. 10.3.5)

When a bolt is subjected to direct axial tension (e.g., hanger connections, bracket tension):

Tdb=Tnbγmb=0.90⋅fub⋅Anbγmb≤fyb⋅Asb⋅γmbγm0\boxed{T_{db} = \frac{T_{nb}}{\gamma_{mb}} = \frac{0.90 \cdot f_{ub} \cdot A_{nb}}{\gamma_{mb}} \le \frac{f_{yb} \cdot A_{sb} \cdot \gamma_{mb}}{\gamma_{m0}}}

For standard Class 4.6 bolts with γmb=1.25\gamma_{mb} = 1.25:

Tdb=0.90×400×Anb1.25=288⋅Anb NT_{db} = \frac{0.90 \times 400 \times A_{nb}}{1.25} = 288 \cdot A_{nb}\text{ N}

4.3.4 Bolt Value (VbV_b) & Number of Bolts Required

The design capacity of a single fastener in a shear connection is termed the Bolt Value (VbV_b):

Vb=min⁡(Vdsb,  Vdpb)\boxed{V_b = \min \left( V_{dsb}, \; V_{dpb} \right)}

For a connection transmitting a total factored shear load PuP_u:

n=PuVb\boxed{n = \frac{P_u}{V_b}}

(Always rounded up to the next whole integer).

4.3.5 Combined Shear and Tension Interaction (IS 800:2007 Cl. 10.3.6)

When a bearing bolt is subjected to simultaneous factored shear VsbV_{sb} and factored tension TbT_b:

(VsbVdsb)2+(TbTdb)2≤1.0\boxed{\left( \frac{V_{sb}}{V_{dsb}} \right)^2 + \left( \frac{T_b}{T_{db}} \right)^2 \le 1.0}

This elliptical interaction profile accounts for the multi-axial von Mises yield criterion and plastic redistributive capacity of ductile mild steel bolts.


4.4 Design Capacity of HSFG Friction-Grip Bolts (IS 800:2007 Cl. 10.4)

4.4.1 Minimum Bolt Tension / Proof Load (F0F_0)

HSFG bolts are pre-tensioned to a minimum clamping force specified as 70%70\% of their nominal tensile capacity:

F0=0.70⋅fub⋅Anb\boxed{F_0 = 0.70 \cdot f_{ub} \cdot A_{nb}}

4.4.2 Design Slip Resistance (VdsfV_{dsf}) (Cl. 10.4.3)

The design resistance to relative slip between connected plies is:

Vdsf=Vnsfγmf=μf⋅ne⋅Kh⋅F0γmf\boxed{V_{dsf} = \frac{V_{nsf}}{\gamma_{mf}} = \frac{\mu_f \cdot n_e \cdot K_h \cdot F_0}{\gamma_{mf}}}

where:

  • μf\mu_f = Slip factor (coefficient of friction at interface):
    • Normal clean mill scale steel surface: μf≈0.20−0.30\mu_f \approx 0.20 - 0.30.
    • Blast-cleaned / grit-blasted surface: μf≈0.40−0.50\mu_f \approx 0.40 - 0.50.
    • Blast-cleaned with spray metal coating (zinc/aluminum): μf≈0.55\mu_f \approx 0.55.
  • nen_e = Number of effective friction slip interfaces:
    • Lap joint: ne=1n_e = 1.
    • Double cover butt joint: ne=2n_e = 2.
  • KhK_h = Hole clearance factor:
    • Standard clearance holes: Kh=1.0K_h = 1.0.
    • Oversized or short slotted holes: Kh=0.85K_h = 0.85.
    • Long slotted holes: Kh=0.70K_h = 0.70.
  • γmf\gamma_{mf} = Partial safety factor for slip resistance:
    • Serviceability Limit State: γmf=1.10\gamma_{mf} = \mathbf{1.10} (joint must not slip under normal working loads).
    • Ultimate Limit State: γmf=1.25\gamma_{mf} = \mathbf{1.25} (slip constitutes catastrophic limit state).

4.4.3 Combined Shear and Tension for HSFG Bolts (Cl. 10.4.3.4)

When an external tension force TeT_e acts on an HSFG connection, it pulls the plates apart, directly reducing the normal clamping contact pressure F0F_0:

(VsfVdsf)+(TfTdf)≤1.0\boxed{\left( \frac{V_{sf}}{V_{dsf}} \right) + \left( \frac{T_f}{T_{df}} \right) \le 1.0}

Equivalently, the effective slip resistance is reduced to:

Vdsf′=μf⋅ne⋅Kh⋅(F0−0.80Te)γmfV_{dsf}' = \frac{\mu_f \cdot n_e \cdot K_h \cdot \left( F_0 - 0.80 T_e \right)}{\gamma_{mf}}

where 0.800.80 is a reduction factor accounting for prying and elastic deformation.


4.5 Plate Tensile Rupture & Joint Efficiency

4.5.1 Net Effective Plate Area (AnetA_{net})

Presence of bolt holes reduces the cross-sectional area of connected plates:

  • For a straight chain of nn bolt holes across plate width BB and thickness tt: Anet=(B−n⋅d0)⋅tA_{net} = \left( B - n \cdot d_0 \right) \cdot t
  • For staggered bolt patterns with gauge gg and staggered pitch psp_s: Anet=[B−n⋅d0+∑ps24g]⋅tA_{net} = \left[ B - n \cdot d_0 + \sum \frac{p_s^2}{4 g} \right] \cdot t

4.5.2 Design Tensile Strength of Net Section (TdnT_{dn}) (Cl. 6.3.1)

Tdn=0.90⋅Anet⋅fuγm1\boxed{T_{dn} = \frac{0.90 \cdot A_{net} \cdot f_u}{\gamma_{m1}}}

where fu=410 N/mm2f_u = 410\text{ N/mm}^2 for Fe 410 steel and γm1=1.25\gamma_{m1} = 1.25.

4.5.3 Gross Section Yielding Strength of Plate (TdgT_{dg}) (Cl. 6.2)

Tdg=Ag⋅fyγm0=B⋅t⋅fyγm0\boxed{T_{dg} = \frac{A_g \cdot f_y}{\gamma_{m0}} = \frac{B \cdot t \cdot f_y}{\gamma_{m0}}}

where γm0=1.10\gamma_{m0} = 1.10.

4.5.4 Joint Efficiency (η\eta)

η=Design Strength of JointGross Design Tensile Strength of Solid Plate (Tdg)×100%\boxed{\eta = \frac{\text{Design Strength of Joint}}{\text{Gross Design Tensile Strength of Solid Plate } (T_{dg})} \times 100\%}

where:

Design Strength of Joint=min⁡(n⋅Vb,  Tdn,  Tdb,block)\text{Design Strength of Joint} = \min \left( n \cdot V_b, \; T_{dn}, \; T_{db,block} \right)

5. Detailing Rules and Codal Mandates (IS 800:2007 Cl. 10.2)

        |<--- e --->|<-------- p -------->|<--- e --->|
        +-----------+---------------------+-----------+  ---
        |           |                     |           |   ^
        |     O     |          O          |     O     |   | e' (Edge distance)
        |           |                     |           |   v
        |           |                     |           |  ---
        |           |                     |           |   ^
        |           |                     |           |   | g (Gauge)
        |           |                     |           |   v
        |     O     |          O          |     O     |  ---
        |           |                     |           |   ^
        |           |                     |           |   | e' (Edge distance)
        +-----------+---------------------+-----------+  ---
        |=============================================> Load Direction
  1. Minimum Pitch (pmin⁡p_{\min}): pmin⁡=2.5⋅dp_{\min} = 2.5 \cdot d Prevents overlapping of localized plastic bearing zones in adjacent holes and provides physical clearance for tightening sockets.
  2. Maximum Pitch (pmax⁡p_{\max}):
    • For members in tension: pmax⁡=min⁡(16t,  200 mm)p_{\max} = \min \left( 16 t, \; 200\text{ mm} \right)
    • For members in compression: pmax⁡=min⁡(12t,  200 mm)p_{\max} = \min \left( 12 t, \; 200\text{ mm} \right) (prevents local buckling of plies between fasteners).
    • If bolts are staggered and gauge g≤75 mmg \le 75\text{ mm}, the above limits may be increased by 50%50\% (i.e., min⁡(24t,300 mm)\min(24 t, 300\text{ mm}) for tension, min⁡(18t,300 mm)\min(18 t, 300\text{ mm}) for compression).
    • For tacking fasteners (not carrying calculated load): min⁡(32t,300 mm)\min(32 t, 300\text{ mm}) for unexposed, or min⁡(16t,200 mm)\min(16 t, 200\text{ mm}) if exposed to weather.
  3. Minimum Edge and End Distances (emin⁡e_{\min}):
    • For sheared, cropped, or hand-flame cut edges: emin⁡=1.7⋅d0e_{\min} = 1.7 \cdot d_0
    • For rolled, machine-flame cut, sawn, or planed edges: emin⁡=1.5⋅d0e_{\min} = 1.5 \cdot d_0
  4. Maximum Edge Distance (emax⁡e_{\max}):
    • In ordinary non-corrosive environments: emax⁡=12⋅t⋅ϵe_{\max} = 12 \cdot t \cdot \epsilon (where ϵ=250/fy\epsilon = \sqrt{250/f_y}).
    • In corrosive / exposed environments: emax⁡=40 mm+4te_{\max} = 40\text{ mm} + 4 t.

6. SVG Diagrams and Visual Explanations

6.1 Bolted Connection Detailing Geometry & The Six Failure Modes

The following original diagram details joint geometry parameters (pitch pp, gauge gg, end distance ee, edge distance e′e') and illustrates the six fundamental structural failure modes encountered in bolted connections.

Bolted Connection Geometry and Failure Modes

6.2 Bearing Bolts vs HSFG Friction Grip Fasteners & Interaction Curves

The following diagram contrasts the physical load transfer mechanisms of bearing bolts (hole wall contact) versus HSFG friction grip bolts (clamping pre-tension F0F_0), and compares their interaction response curves under combined shear and tension.

Bearing vs HSFG Friction Mechanics and Interaction

7. Solved Numerical Examples

7.1 Example 1: Design of a Bearing-Type Bolted Lap Joint under Tension

Problem Statement:
Two plates of width B=200 mmB = 200\text{ mm}, thickness t1=10 mmt_1 = 10\text{ mm} and t2=12 mmt_2 = 12\text{ mm} of Fe 410 grade steel (fu=410 N/mm2,fy=250 N/mm2f_u = 410\text{ N/mm}^2, f_y = 250\text{ N/mm}^2) are connected by a lap joint to transmit a factored tensile load Pu=150.0 kNP_u = 150.0\text{ kN}. The bolts used are Class 4.6 with nominal diameter d=16 mmd = 16\text{ mm}.

  1. Determine the design shear capacity and bearing capacity of a single bolt.
  2. Compute the Bolt Value and find the required number of bolts.
  3. Check the net tensile capacity of the plate across the critical bolt line and determine the joint efficiency η\eta.

Step-by-Step Solution:

  • Step 1: Bolt Geometry & Section Properties

    • Nominal diameter d=16 mmd = 16\text{ mm}.
    • Standard hole diameter (for 16 mm16\text{ mm} bolt, add +2 mm+2\text{ mm}): d0=16+2=18.0 mmd_0 = 16 + 2 = \mathbf{18.0\text{ mm}}
    • Nominal shank area: Asb=π4×162=201.06 mm2A_{sb} = \frac{\pi}{4} \times 16^2 = 201.06\text{ mm}^2
    • Net tensile area at threads (IS 800:2007 Cl. 10.3.3): Anb=0.78×Asb=0.78×201.06=156.83 mm2A_{nb} = 0.78 \times A_{sb} = 0.78 \times 201.06 = \mathbf{156.83\text{ mm}^2}
    • For Class 4.6 bolts: fub=400 N/mm2,fyb=240 N/mm2,γmb=1.25f_{ub} = 400\text{ N/mm}^2, f_{yb} = 240\text{ N/mm}^2, \gamma_{mb} = 1.25.
  • Step 2: Design Shear Capacity of Bolt (VdsbV_{dsb})

    • Single shear plane passing through threads (nn=1,ns=0n_n = 1, n_s = 0): Vnsb=fub3(nnAnb+nsAsb)=4003×156.83=230.94×156.83=36217 N=36.22 kNV_{nsb} = \frac{f_{ub}}{\sqrt{3}} \left( n_n A_{nb} + n_s A_{sb} \right) = \frac{400}{\sqrt{3}} \times 156.83 = 230.94 \times 156.83 = 36217\text{ N} = 36.22\text{ kN} Vdsb=Vnsbγmb=36.22 kN1.25=28.97 kNV_{dsb} = \frac{V_{nsb}}{\gamma_{mb}} = \frac{36.22\text{ kN}}{1.25} = \mathbf{28.97\text{ kN}}
  • Step 3: Design Bearing Capacity of Bolt (VdpbV_{dpb})

    • Effective bearing plate thickness: t=min⁡(10,12)=10 mmt = \min(10, 12) = 10\text{ mm}.
    • Provide standard detailing distances: e=1.5d0=1.5×18=27 mm  ⟹  Adopt e=30 mm(Machine cut)e = 1.5 d_0 = 1.5 \times 18 = 27\text{ mm} \implies \text{Adopt } e = \mathbf{30\text{ mm}} \quad (\text{Machine cut}) p=2.5d=2.5×16=40 mm  ⟹  Adopt p=50 mmp = 2.5 d = 2.5 \times 16 = 40\text{ mm} \implies \text{Adopt } p = \mathbf{50\text{ mm}}
    • Evaluate kbk_b: kb1=e3d0=303×18=3054=0.5556k_{b1} = \frac{e}{3 d_0} = \frac{30}{3 \times 18} = \frac{30}{54} = 0.5556 kb2=p3d0−0.25=5054−0.25=0.9259−0.25=0.6759k_{b2} = \frac{p}{3 d_0} - 0.25 = \frac{50}{54} - 0.25 = 0.9259 - 0.25 = 0.6759 kb3=fubfu=400410=0.9756k_{b3} = \frac{f_{ub}}{f_u} = \frac{400}{410} = 0.9756 kb4=1.0k_{b4} = 1.0 kb=min⁡(0.5556,0.6759,0.9756,1.0)=0.5556k_b = \min(0.5556, 0.6759, 0.9756, 1.0) = \mathbf{0.5556}
    • Nominal bearing strength: Vnpb=2.5⋅kb⋅d⋅t⋅fu=2.5×0.5556×16×10×410=91118 N=91.12 kNV_{npb} = 2.5 \cdot k_b \cdot d \cdot t \cdot f_u = 2.5 \times 0.5556 \times 16 \times 10 \times 410 = 91118\text{ N} = 91.12\text{ kN}
    • Design bearing strength: Vdpb=Vnpbγmb=91.12 kN1.25=72.89 kNV_{dpb} = \frac{V_{npb}}{\gamma_{mb}} = \frac{91.12\text{ kN}}{1.25} = \mathbf{72.89\text{ kN}}
  • Step 4: Bolt Value & Required Number of Bolts

    Vb=min⁡(Vdsb,Vdpb)=min⁡(28.97 kN,72.89 kN)=28.97 kN(Governed by shear)V_b = \min(V_{dsb}, V_{dpb}) = \min(28.97\text{ kN}, 72.89\text{ kN}) = \mathbf{28.97\text{ kN}} \quad (\text{Governed by shear}) Number of bolts n=PuVb=150.0 kN28.97 kN=5.18  ⟹  Provide 6 bolts\text{Number of bolts } n = \frac{P_u}{V_b} = \frac{150.0\text{ kN}}{28.97\text{ kN}} = 5.18 \implies \mathbf{\text{Provide 6 bolts}}

    (Arranged in 2 rows of 3 bolts each).

  • Step 5: Net Section Tensile Rupture Check (TdnT_{dn})

    • Across the critical end bolt line (2 bolt holes across width B=200 mmB = 200\text{ mm}): Anet=(B−nrow⋅d0)⋅t=(200−2×18)×10=164×10=1640 mm2A_{net} = \left( B - n_{row} \cdot d_0 \right) \cdot t = \left( 200 - 2 \times 18 \right) \times 10 = 164 \times 10 = 1640\text{ mm}^2 Tdn=0.90⋅Anet⋅fuγm1=0.90×1640×4101.25=484128 N=484.13 kN>150 kN(SAFE)T_{dn} = \frac{0.90 \cdot A_{net} \cdot f_u}{\gamma_{m1}} = \frac{0.90 \times 1640 \times 410}{1.25} = 484128\text{ N} = \mathbf{484.13\text{ kN}} > 150\text{ kN} \quad (\mathbf{SAFE})
  • Step 6: Joint Efficiency (η\eta)

    • Gross plate tensile strength: Tdg=Ag⋅fyγm0=200×10×2501.10=454545 N=454.55 kNT_{dg} = \frac{A_g \cdot f_y}{\gamma_{m0}} = \frac{200 \times 10 \times 250}{1.10} = 454545\text{ N} = \mathbf{454.55\text{ kN}}
    • Total joint shear strength =6×28.97 kN=173.82 kN= 6 \times 28.97\text{ kN} = 173.82\text{ kN}.
    • Governing joint strength =min⁡(173.82 kN,484.13 kN)=173.82 kN= \min(173.82\text{ kN}, 484.13\text{ kN}) = 173.82\text{ kN}. η=(173.82454.55)×100%=38.24%\eta = \left( \frac{173.82}{454.55} \right) \times 100\% = \mathbf{38.24\%}

7.2 Example 2: HSFG (Slip-Critical) Double Cover Butt Joint

Problem Statement:
A double cover butt joint connects two main plates of width B=250 mmB = 250\text{ mm} and thickness t=16 mmt = 16\text{ mm} carrying a working axial tensile load P=300 kNP = 300\text{ kN} (factored load Pu=1.5×300=450.0 kNP_u = 1.5 \times 300 = 450.0\text{ kN}). Two cover plates of thickness tc=10 mmt_c = 10\text{ mm} each are provided. HSFG bolts of Class 8.8 with nominal diameter d=20 mmd = 20\text{ mm} are to be used in standard clearance holes. The slip factor of the interface is μf=0.40\mu_f = 0.40.

  1. Calculate the minimum proof load (clamping force F0F_0) per bolt.
  2. Determine the design slip resistance per bolt under both serviceability (γmf=1.10\gamma_{mf} = 1.10) and ultimate limit state (γmf=1.25\gamma_{mf} = 1.25).
  3. Determine the required number of HSFG bolts on each side of the joint.

Step-by-Step Solution:

  • Step 1: Fastener Geometric Properties

    • Bolt diameter d=20 mmd = 20\text{ mm}, standard hole d0=20+2=22 mmd_0 = 20 + 2 = 22\text{ mm}.
    • Nominal shank area: Asb=π4×202=314.16 mm2A_{sb} = \frac{\pi}{4} \times 20^2 = 314.16\text{ mm}^2.
    • Net tensile area at threads: Anb=0.78×314.16=245.04 mm2A_{nb} = 0.78 \times 314.16 = \mathbf{245.04\text{ mm}^2}
    • For Class 8.8 HSFG bolts: fub=800 N/mm2,fyb=640 N/mm2f_{ub} = 800\text{ N/mm}^2, f_{yb} = 640\text{ N/mm}^2.
  • Step 2: Minimum Proof Load (F0F_0)

    • Minimum clamping force per bolt (IS 800:2007 Cl. 10.4.3.1): F0=0.70⋅fub⋅Anb=0.70×800 N/mm2×245.04 mm2=137222 N=137.22 kNF_0 = 0.70 \cdot f_{ub} \cdot A_{nb} = 0.70 \times 800\text{ N/mm}^2 \times 245.04\text{ mm}^2 = 137222\text{ N} = \mathbf{137.22\text{ kN}}
  • Step 3: Design Slip Resistance per Bolt (VdsfV_{dsf})

    • Double cover butt joint provides two effective friction interfaces: ne=2n_e = 2.
    • Standard clearance holes: Kh=1.0K_h = 1.0.
    • Nominal slip resistance: Vnsf=μf⋅ne⋅Kh⋅F0=0.40×2×1.0×137.22 kN=109.78 kNV_{nsf} = \mu_f \cdot n_e \cdot K_h \cdot F_0 = 0.40 \times 2 \times 1.0 \times 137.22\text{ kN} = \mathbf{109.78\text{ kN}}
    • At Serviceability Limit State (γmf=1.10\gamma_{mf} = 1.10): Vdsf,serv=109.781.10=99.80 kNV_{dsf,serv} = \frac{109.78}{1.10} = \mathbf{99.80\text{ kN}}
    • At Ultimate Limit State (γmf=1.25\gamma_{mf} = 1.25): Vdsf,ult=109.781.25=87.82 kNV_{dsf,ult} = \frac{109.78}{1.25} = \mathbf{87.82\text{ kN}}
  • Step 4: Number of HSFG Bolts Required per Side

    • Checking against ultimate factored load Pu=450.0 kNP_u = 450.0\text{ kN}: nult=PuVdsf,ult=450.0 kN87.82 kN=5.12  ⟹  Provide 6 bolts per siden_{ult} = \frac{P_u}{V_{dsf,ult}} = \frac{450.0\text{ kN}}{87.82\text{ kN}} = 5.12 \implies \mathbf{\text{Provide 6 bolts per side}}
    • Checking against working service load P=300.0 kNP = 300.0\text{ kN}: nserv=PVdsf,serv=300.0 kN99.80 kN=3.01  ⟹  4 boltsn_{serv} = \frac{P}{V_{dsf,serv}} = \frac{300.0\text{ kN}}{99.80\text{ kN}} = 3.01 \implies 4\text{ bolts}
    • The design is governed by the ultimate limit state: Provide 6 HSFG bolts on each side of the splice (total 12 bolts in joint).

7.3 Example 3: Verification of Bolted Connection under Combined Shear and Tension

Problem Statement:
A column-bracket connection transmits a factored shear force Vu=90.0 kNV_u = 90.0\text{ kN} and a factored tensile force Tu=60.0 kNT_u = 60.0\text{ kN}. The joint consists of 4 bolts of Class 4.6, d=20 mmd = 20\text{ mm} connecting a 12 mm12\text{ mm} thick bracket plate (fu=410 N/mm2f_u = 410\text{ N/mm}^2). Spacing: pitch p=60 mmp = 60\text{ mm}, end distance e=35 mme = 35\text{ mm}.

  1. Compute the design shear capacity (VdsbV_{dsb}), design bearing capacity (VdpbV_{dpb}), and design tensile capacity (TdbT_{db}) per bolt.
  2. Verify the structural safety of the fasteners using the IS 800:2007 interaction criterion.

Step-by-Step Solution:

  • Step 1: Applied Forces per Fastener

    Vsb=Vun=90.0 kN4=22.50 kNV_{sb} = \frac{V_u}{n} = \frac{90.0\text{ kN}}{4} = \mathbf{22.50\text{ kN}} Tb=Tun=60.0 kN4=15.00 kNT_b = \frac{T_u}{n} = \frac{60.0\text{ kN}}{4} = \mathbf{15.00\text{ kN}}
  • Step 2: Bolt Capacities

    • Bolt diameter d=20 mm,d0=22 mm,Asb=314.16 mm2,Anb=245.04 mm2d = 20\text{ mm}, d_0 = 22\text{ mm}, A_{sb} = 314.16\text{ mm}^2, A_{nb} = 245.04\text{ mm}^2.
    • Shear Capacity (VdsbV_{dsb}): Vdsb=fub⋅Anb3⋅γmb=400×245.043×1.25=45271 N=45.27 kNV_{dsb} = \frac{f_{ub} \cdot A_{nb}}{\sqrt{3} \cdot \gamma_{mb}} = \frac{400 \times 245.04}{\sqrt{3} \times 1.25} = 45271\text{ N} = \mathbf{45.27\text{ kN}}
    • Bearing Capacity (VdpbV_{dpb}): kb=min⁡(353×22,  603×22−0.25,  400410,  1.0)=min⁡(0.5303,  0.6591,  0.9756,  1.0)=0.5303k_b = \min \left( \frac{35}{3 \times 22}, \; \frac{60}{3 \times 22} - 0.25, \; \frac{400}{410}, \; 1.0 \right) = \min(0.5303, \; 0.6591, \; 0.9756, \; 1.0) = \mathbf{0.5303} Vnpb=2.5×0.5303×20×12×410=130454 N=130.45 kNV_{npb} = 2.5 \times 0.5303 \times 20 \times 12 \times 410 = 130454\text{ N} = 130.45\text{ kN} Vdpb=130.451.25=104.36 kNV_{dpb} = \frac{130.45}{1.25} = \mathbf{104.36\text{ kN}} Design Shear Strength Vdb=min⁡(45.27,104.36)=45.27 kN\text{Design Shear Strength } V_{db} = \min(45.27, 104.36) = \mathbf{45.27\text{ kN}}
    • Tensile Capacity (TdbT_{db}): Tdb=0.90⋅fub⋅Anbγmb=0.90×400×245.041.25=70572 N=70.57 kNT_{db} = \frac{0.90 \cdot f_{ub} \cdot A_{nb}}{\gamma_{mb}} = \frac{0.90 \times 400 \times 245.04}{1.25} = 70572\text{ N} = \mathbf{70.57\text{ kN}} (Tensile yield check: fybAsbγmbγm0=240×314.16×1.251.10=85.68 kN>70.57 kNf_{yb} A_{sb} \frac{\gamma_{mb}}{\gamma_{m0}} = 240 \times 314.16 \times \frac{1.25}{1.10} = 85.68\text{ kN} > 70.57\text{ kN}).
  • Step 3: Interaction Criterion (IS 800:2007 Cl. 10.3.6)

    (VsbVdb)2+(TbTdb)2≤1.0\left( \frac{V_{sb}}{V_{db}} \right)^2 + \left( \frac{T_b}{T_{db}} \right)^2 \le 1.0 (22.5045.27)2+(15.0070.57)2=(0.4970)2+(0.2125)2\left( \frac{22.50}{45.27} \right)^2 + \left( \frac{15.00}{70.57} \right)^2 = \left( 0.4970 \right)^2 + \left( 0.2125 \right)^2 =0.2470+0.0452=0.2922≤1.0(SAFE & COMPLIANT)= 0.2470 + 0.0452 = \mathbf{0.2922} \le 1.0 \quad (\mathbf{SAFE \ \& \ COMPLIANT})

8. Common Pitfalls, Misconceptions, and Examination Traps

  1. Confusing Nominal Shank Area with Net Tensile Area:
    • Trap: Using Asb=π4d2A_{sb} = \frac{\pi}{4} d^2 for shear calculation when threads are in the shear plane.
    • Reality: Standard practice assumes threads cross the shear plane unless specifically detailed otherwise. Always use Anb≈0.78AsbA_{nb} \approx 0.78 A_{sb} for VdsbV_{dsb} and TdbT_{db}.
  2. Double Shear Bearing Thickness Pitfall:
    • Trap: In a double cover butt joint, taking t=tmain+2tcovert = t_{\text{main}} + 2 t_{\text{cover}}.
    • Reality: Connected plates push in opposite directions. The critical bearing thickness is t=min⁡(tmain,2tcover)t = \min(t_{\text{main}}, 2 t_{\text{cover}}).
  3. Misinterpreting kbk_b Calculation:
    • Trap: Omitting the −0.25-0.25 factor in the pitch term (p3d0−0.25)\left(\frac{p}{3 d_0} - 0.25\right) or dividing by 3d3 d instead of 3d03 d_0.
    • Reality: Hole diameter d0d_0 must be used in the denominator, not nominal bolt diameter dd.
  4. Interaction Formula Exponents:
    • Trap: Applying linear interaction (V/Vd)+(T/Td)≤1.0(V/V_d) + (T/T_d) \le 1.0 to ordinary bearing bolts.
    • Reality: Bearing bolts follow an elliptical interaction (V/Vd)2+(T/Td)2≤1.0(V/V_d)^2 + (T/T_d)^2 \le 1.0. HSFG friction bolts follow a linear interaction (V/Vd)+(T/Td)≤1.0(V/V_d) + (T/T_d) \le 1.0 because tension directly relieves the clamping friction.
  5. Pitch vs Gauge Orientation:
    • Trap: Swapping pitch and gauge.
    • Reality: Pitch (pp) is measured parallel to the line of action of load. Gauge (gg) is measured perpendicular to the line of action of load.

9. Comparative Analysis and Summary Tables

9.1 Bearing-Type Bolts vs High-Strength Friction Grip (HSFG) Bolts

Characteristic Bearing-Type Bolts (Class 4.6) HSFG Bolts (Class 8.8 / 10.9)
Material Low carbon / Mild steel Medium carbon / Quenched & tempered alloy
Load Transfer Mechanism Bearing on hole wall + Shear across shank Interfacial friction between clamped plates
Hole Clearance Contact Shank bears directly against hole edge Shank does NOT touch hole edge under service
Initial Tightening Snug-tight / normal wrenching Calibrated proof tension F0=0.70fubAnbF_0 = 0.70 f_{ub} A_{nb}
Joint Slip Slips into bearing before taking full load Zero slip under serviceability limit state
Fatigue Performance Poor (stress concentrations at bearing face) Superior (no stress reversal on shank)
Combined V & T Interaction Elliptical: (V/Vd)2+(T/Td)2≤1.0(V/V_d)^2 + (T/T_d)^2 \le 1.0 Linear: (V/Vd)+(T/Td)≤1.0(V/V_d) + (T/T_d) \le 1.0
Typical Use Static roofs, secondary trusses, purlins Bridges, cranes, dynamic towers, seismic frames

10. Exam-Specific Focus and Formula Cheat Sheet

10.1 Must-Remember Formulas for Quick Objective Calculations

d0=d+1 mm  (12−14 mm),d0=d+2 mm  (16−24 mm),d0=d+3 mm  (>24 mm)\boxed{d_0 = d + 1\text{ mm} \; (12-14\text{ mm}), \quad d_0 = d + 2\text{ mm} \; (16-24\text{ mm}), \quad d_0 = d + 3\text{ mm} \; (>24\text{ mm})} Anb=0.78⋅π4d2\boxed{A_{nb} = 0.78 \cdot \frac{\pi}{4} d^2} Vdsb=fub⋅Anb3⋅1.25(Single Shear, Thread in Plane)\boxed{V_{dsb} = \frac{f_{ub} \cdot A_{nb}}{\sqrt{3} \cdot 1.25} \quad (\text{Single Shear, Thread in Plane})} Vdpb=2.5⋅kb⋅d⋅t⋅fu1.25\boxed{V_{dpb} = \frac{2.5 \cdot k_b \cdot d \cdot t \cdot f_u}{1.25}} kb=min⁡(e3d0,  p3d0−0.25,  fubfu,  1.0)\boxed{k_b = \min \left( \frac{e}{3 d_0}, \; \frac{p}{3 d_0}-0.25, \; \frac{f_{ub}}{f_u}, \; 1.0 \right)} Tdb=0.90⋅fub⋅Anb1.25\boxed{T_{db} = \frac{0.90 \cdot f_{ub} \cdot A_{nb}}{1.25}} F0=0.70⋅fub⋅Anb(HSFG Proof Load)\boxed{F_0 = 0.70 \cdot f_{ub} \cdot A_{nb} \quad (\text{HSFG Proof Load})} Vdsf=μf⋅ne⋅Kh⋅F0γmf(γmf=1.10 serv,  1.25 ult)\boxed{V_{dsf} = \frac{\mu_f \cdot n_e \cdot K_h \cdot F_0}{\gamma_{mf}} \quad (\gamma_{mf} = 1.10 \text{ serv}, \; 1.25 \text{ ult})} pmin⁡=2.5d,emin⁡=1.5d0 (machine cut),emin⁡=1.7d0 (hand cut)\boxed{p_{\min} = 2.5 d, \quad e_{\min} = 1.5 d_0 \text{ (machine cut)}, \quad e_{\min} = 1.7 d_0 \text{ (hand cut)}} pmax⁡=min⁡(16t,200 mm) (tension),min⁡(12t,200 mm) (compression)\boxed{p_{\max} = \min(16 t, 200\text{ mm}) \text{ (tension)}, \quad \min(12 t, 200\text{ mm}) \text{ (compression)}}

11. Practice Problems and Self-Assessment with Numerical Answers

  1. Practice Problem 1: Calculate the bolt value of an M20 bolt of Class 4.6 in single shear connecting two 10 mm10\text{ mm} thick plates of Fe 410 steel. Given: e=35 mm,p=60 mme = 35\text{ mm}, p = 60\text{ mm}.
    Answer: d0=22 mm,Anb=245.04 mm2d_0 = 22\text{ mm}, A_{nb} = 245.04\text{ mm}^2. Vdsb=45.27 kNV_{dsb} = \mathbf{45.27\text{ kN}}. kb=min⁡(0.5303,0.6591,0.9756,1.0)=0.5303k_b = \min(0.5303, 0.6591, 0.9756, 1.0) = 0.5303. Vdpb=2.5×0.5303×20×10×4101.25=86.97 kNV_{dpb} = \frac{2.5 \times 0.5303 \times 20 \times 10 \times 410}{1.25} = \mathbf{86.97\text{ kN}}. Bolt Value Vb=45.27 kNV_b = \mathbf{45.27\text{ kN}}.

  2. Practice Problem 2: An M24 HSFG bolt of Class 8.8 connects two plates in a lap joint (ne=1n_e = 1). The surfaces are blast cleaned (μf=0.45\mu_f = 0.45). Standard clearance holes are used (Kh=1.0K_h = 1.0). Compute the design slip resistance at serviceability (γmf=1.10\gamma_{mf} = 1.10).
    Answer: Anb=0.78×(π4×242)=352.86 mm2A_{nb} = 0.78 \times (\frac{\pi}{4} \times 24^2) = 352.86\text{ mm}^2. Proof load F0=0.70×800×352.86=197.60 kNF_0 = 0.70 \times 800 \times 352.86 = 197.60\text{ kN}. Nominal slip Vnsf=0.45×1×1.0×197.60=88.92 kNV_{nsf} = 0.45 \times 1 \times 1.0 \times 197.60 = 88.92\text{ kN}. Vdsf=88.92/1.10=80.84 kNV_{dsf} = 88.92 / 1.10 = \mathbf{80.84\text{ kN}}.

  3. Practice Problem 3: A plate of size 180 mm×8 mm180\text{ mm} \times 8\text{ mm} (Fe 410, fu=410 N/mm2,fy=250 N/mm2f_u = 410\text{ N/mm}^2, f_y = 250\text{ N/mm}^2) is connected to a gusset plate using 3 bolts of 16 mm16\text{ mm} diameter in a single line along the load direction (1 bolt per cross-section). Find the design tensile rupture strength of the plate.
    Answer: Critical section has 1 hole (d0=18 mmd_0 = 18\text{ mm}). Anet=(180−1×18)×8=162×8=1296 mm2A_{net} = (180 - 1 \times 18) \times 8 = 162 \times 8 = 1296\text{ mm}^2. Tdn=0.90×1296×4101.25=382.58 kNT_{dn} = \frac{0.90 \times 1296 \times 410}{1.25} = \mathbf{382.58\text{ kN}}.


12. Standard References and Further Reading

  1. IS 800:2007: General Construction in Steel — Code of Practice (Third Revision), Bureau of Indian Standards, New Delhi. (Section 10: Connections).
  2. Subramanian, N.: Design of Steel Structures, Oxford University Press, New Delhi. (Chapter 5: Bolted Connections).
  3. Duggal, S.K.: Limit State Design of Steel Structures, 3rd Edition, McGraw Hill Education.
  4. Bhavikatti, S.S.: Design of Steel Structures (By Limit State Method as Per IS: 800-2007), I.K. International Publishing House.
  5. IS 3757:1985: High Strength Structural Bolts, Bureau of Indian Standards.